Site Details: New Farm
Dumfriesshire
DG10 9LG
Water type: Freshwater
Inspection reports
Case Number: 2020-0510
Download
Paperwork completed remotely on 25/11/2020 and physical inspection conducted on the 18/11/2020 - mortality records submitted before physical inspection.
There has historically been issues on site with eye flukes. To resolve this the operator has installed a new disk filter system and so far this has proved to be effective.
No issues on site, fish were active and displayed a good feed response when ponds were approached.
There has been some minor issues on site with heron and the site operator is considering installing lines across the site.
Incinerator onsite is used to dispose of waste from Moffat Water.
Site temperature used as inspector's thermometer not working [Original PDF]
Case Number: 2022-0033
Download
Remote inspection on 23/02/2022 by , supervised by .
No site wide fallow planned but ponds can now be completely emptied and fallowed individually, thanks to the recently installed disc filter system. Filter fitted to prevent eye fluke issues on site.
Site inspection and VMD sampling done by , observed by . No issues on site, the fish had a good feed response when the ponds were approached. Site thermometer used for biosecurity reasons. [Original PDF]